Model Compare: Review the Changes

After the Compare command is run, the Model Compare window displays the model with colored highlights and other feedback on changes.

The Model Compare palette is docked at the left edge of this window (this palette cannot be moved).

Note: By default, the Model Compare palette lists all 3D model changes resulting from the Compare process. To filter the list of displayed changes, see Filter Changes Shown in Model Compare Palette.

Topics in this section:

Set Model Appearance

List of Model Changes

Selection in Model Compare Window

Changes By Parameter Set

Set Model Appearance

The “Model 1 only” and “Model 2 only” elements are shown in their respective colors.

In this example:

The red wall is “Model 1 only”, because it was deleted.

The blue wall is “Model 2 only”, because it is a new element.

The slabs and chair objects are shown in a blended (purple) color, to indicate that they have been modified, while remaining in their original position.

Note: Set Model Compare colors at Options > Work Environment > On-Screen View Options.

See Workspace Colors for Model Compare.

In the Appearance section of the Model Compare palette:

Use the top slider to graphically emphasize Model 1 or Model 2. (Here, the slider is in the middle, showing both versions equally.)

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/083_modelcompare/CompareColors1.png 

Use the bottom slider to set the relative visibility of the unchanged model (the set of unaffected or unchecked elements).

Here, the bottom slider is set to hide the unchanged model completely, so all you see are the changes:

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/083_modelcompare/CompareColors2.png 

List of Model Changes

By default, the Model Changes list shows all changed elements, grouped by Status: Modified, Model 1 Only, and Model 2 Only.

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/083_modelcompare/ModelChangesList.png 

To customize this list, use the filter and settings buttons.

See also Filter Changes Shown in Model Compare Palette.

Selection in Model Compare Window

Select any item from the Model Changes list to select the corresponding element in the Model Compare window.

Here, a modified Slab is selected:

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/083_modelcompare/SelectSlab.png 

The same works the other way around: you can select any changed element in the Model Compare window: it is then selected in the Model Changes list, too.

Note: In the Model Compare window, you can only select elements that are also listed in the Model Changes list. Unchanged elements, even if displayed in the window, cannot be selected here (see cursor feedback).

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/083_modelcompare/NoSelection.png 

Select Elements By Group

Select a parent item in the list tree to select all its member elements in the Model Compare window.

Show Changed Element in Model

For a selected item in the Model Changes list: use the context menu commands to Show on Floor Plan or Show in 3D.

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/083_modelcompare/ModelChangesList2.png 

Context Menu Commands

For a selected item in the Model Compare window:

Use Hide Selected or Hide Unselected to get a better view of the changed element and/or its environment.

Reverse this command with Unhide All, available in the same context menu.

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/083_modelcompare/HideSelected.png 

Changes By Parameter Set

For the last-selected element in the Model Changes list:

The “Selected Element Changes” icons indicate which parameters have changed. (This is relevant for “Modified” elements in the list.)

Here, a modified object is selected in the list, and in the model.

Below the list, the “Model” icon is active: this indicates that the one or more Model parameters of this chair were modified.

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/083_modelcompare/ModifiedIcons.png 

These parameter sets are the same as in the “Checklist” used to filter the change list in the Model Compare window.

See also Filter by Parameter Sets.

Related Topic:

Create Issue from Model Compare Change List

  • Was this Helpful ?
  • YesNo
Relevant topics
Compare Teamwork Model Versions (Before and After Receiving Changes)
Use this Compare workflow in Teamwork after receiving changes, to see what has changed in the model. There are two “Compare” commands in the Teamwork context. Send and Receive, then Compare Send and Receive as usual. This results in a new local cache (after Receive): the ...
Filter Changes Shown in Model Compare Palette
By default, the Model Compare palette lists all 3D model changes resulting from the Compare process. Use the Filter buttons to narrow the list of changes shown here, and the list format options to display them. Topics in this section: Filter by Element Criteria Filter by ...
Compare [COMPARE]
Compares two strings. Returns 0 if they are equal Returns -1 if text1 precedes text2 in alphanumeric order Returns +1 if text1 comes after ...