Partial Structure Display

The Partial Structure Display function allows you to display construction elements in various ways depending how you define the components of elements.

For example, when collaborating with other designers or with engineers, you may prefer to ignore non-load-bearing walls, and to display/output only the load-bearing components of complex elements.

To switch the preferred Partial Structure Display Option, do one of the following:

Use the Partial Structure Display pop-up from the Quick Options Bar at the bottom of the window

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/050_viewsvb/PSDPopup.png 

Use Document > Partial Structure Display to set these preferences; they will be applied to the current window and can be saved separately for each view.

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/050_viewsvb/PartialStructure.png 

Use the first three options to display or hide the components of composite or complex elements, and column veneers, depending upon how you have defined those components.

See How to Define Components as “Core” or “Finish”.

1.Entire Model: this is the default setting. All parts of the model are displayed.

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/050_viewsvb/EntirePic.png 

2.Without Finishes: Model is displayed without:

skins/components that are defined as “Finish” and

column veneers that are defined as “Finish”

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/050_viewsvb/WithoutPic.png 

3.Core Only: Displays only the structures defined as “Core” (applicable to complex or composite structures, and columns having a veneer)

https://helpcenter.graphisoft.com/wp-content/uploads/archicad-24-reference-guide/050_viewsvb/CorePic.png 

See also Dimension Skins of Composite/Profile Element Automatically.

4.Core of Load-Bearing Elements Only: The fourth option considers all construction elements (not just composite/complex). This option will hide any elements you have classified as “non-load-bearing” or “undefined”.

The “Core of Load-Bearing Elements Only” option has three effects:

-Elements classified as “Non-Load-Bearing” or “Undefined” will be hidden; all elements classified as “Load-Bearing” are displayed

-Load-bearing composite and complex structures are shown with their Core only

-Column veneers defined as “Core” in Column Settings will be shown in addition to the Column cores

Topics in this section:

Applying Partial Structure Settings to Model Windows

Save Partial Structure Settings by View

How to Define Components as “Core” or “Finish”

Visualizing the Entire Model

Partial Structure Display Settings: Effect on Elements

Partial Structure Display Settings in Windows Based on a Source Marker