1.Open Load Manager.
2.Select a Load Group from the list on the left.
3.Adjust its Load Group Settings on the right.
Group Name
Each Load Group must have a unique name.
Group Type
•Permanent
•Variable
•Accidental
•Seismic
•Moving
•Tensioning
•Fire
Load Type for a Load Group
Optionally, enter text to describe the Load Type.
Relation
•Exclusive
•Standard
•Together
Relevant topics
Load Manager (for Load Cases and Load Groups)
Load Manager lists all of the project's Load Cases, organized into Load Groups.
Load Manager is also used to activate a Load Case:
–To activate a Load Case, select it in Load Manager.
–The selected Load Case becomes the visible Load Case for the current view.
...
Load Tool Settings
There are three Load tools in ARCHICAD:
•Structural Point Load
•Structural Line Load
•Structural Surface Load
To open its Settings, double-click the tool in the toolbox.
Point Load Settings
Line Load Settings
Load ...
Load Case Settings
In Load Manager, select a Load Case to access its settings on the right.
Note: The selected Load Case becomes the visible Load Case for the current view.
Case Name:
Each Load Case must have a unique name.
Action Type
Permanent