Intersecting Elements That Don’t Clean Up

Wall-Wall intersections clean up only if their reference lines intersect. (Collision is not supported.)

//helpcenter.graphisoft.com/wp-content/uploads/ac22_help/040-elementsvb/ModelParallelWalls.png          //helpcenter.graphisoft.com/wp-content/uploads/ac22_help/040-elementsvb/ModelParallelWallsSection.png

Column-Column intersections do not clean up when they collide.

Use a profiled column or the Merge Profiles function to achieve special Column intersections.

When placing a Column that will intersect a Composite wall, your choice of Geometry method – wrapped or unwrapped – will affect the display of the wall/column in the Floor Plan.

Slab-Slab intersections do not clean up when they collide.

Mesh is not supported.

Objects are not supported.